Accuracy of deep brain stimulation electrode placement using intraoperative computed tomography without microelectrode recording

Clinical article

View More View Less
  • Department of Neurological Surgery, Oregon Health & Science University, Portland, Oregon
Restricted access

Purchase Now

USD  $45.00

JNS + Pediatrics - 1 year subscription bundle (Individuals Only)

USD  $505.00

JNS + Pediatrics + Spine - 1 year subscription bundle (Individuals Only)

USD  $600.00
Print or Print + Online

Object

In this prospective study the authors' objective was to evaluate the accuracy of deep brain stimulation (DBS) electrode placement using image guidance for direct anatomical targeting with intraoperative CT.

Methods

Preoperative 3-T MR images were merged with intraoperative CT images for planning. Electrode targets were anatomical, based on the MR images. A skull-mounted NexFrame system was used for electrode placement, and all procedures were performed under general anesthesia. After electrode placement, intraoperative CT images were merged with trajectory planning images to calculate accuracy. Accuracy was assessed by both vector error and deviation off the planned trajectory.

Results

Sixty patients (33 with Parkinson disease, 26 with essential tremor, and 1 with dystonia) underwent the procedure. Patient's mean age was 64 ± 9.5 years. Over an 18-month period, 119 electrodes were placed (all bilateral, except one). Electrode implant locations were the ventral intermediate nucleus (VIM), globus pallidus internus (GPI), and subthalamic nucleus (STN) in 25, 23, and 12 patients, respectively. Target accuracy measurements were as follows: mean vector error 1.59 ± 1.11 mm and mean deviation off trajectory 1.24 ± 0.87 mm. There was no statistically significant difference between the accuracy of left and right brain electrodes. There was a statistically significant (negative) correlation between the distance of the closest approach of the electrode trajectory to the ventricular wall of the lateral ventricle and vector error (r2 = −0.339, p < 0.05, n = 76), and the deviation from the planned trajectory (r2 = −0.325, p < 0.05, n = 77). Furthermore, when the distance from the electrode trajectory and the ventricular wall was < 4 mm, the correlation of the ventricular distance to the deviation from the planned trajectory was stronger (r2 = −0.419, p = 0.05, n = 19). Electrodes placed in the GPI were significantly more accurate than those placed in the VIM (p < 0.05). Only 1 of 119 electrodes required intraoperative replacement due to a vector error > 3 mm. In this series there was one infection and no intraparenchymal hemorrhages.

Conclusions

Placement of DBS electrodes using an intraoperative CT scanner and the NexFrame achieves an accuracy that is at least comparable to other methods.

Abbreviations used in this paper:DBS = deep brain stimulation; GPI = globus pallidus internus; MER = microelectrode recording; STN = subthalamic nucleus; VIM = ventral intermediate nucleus.

JNS + Pediatrics - 1 year subscription bundle (Individuals Only)

USD  $505.00

JNS + Pediatrics + Spine - 1 year subscription bundle (Individuals Only)

USD  $600.00

Contributor Notes

Address correspondence to: Ahmed M. Raslan, M.D., Department of Neurological Surgery, Oregon Health & Science University, Mail code CH8N, 3303 SW Bond Avenue, Portland, Oregon 97239-3098. email: raslana@ohsu.edu.

Please include this information when citing this paper: published online May 31, 2013; DOI: 10.3171/2013.4.JNS122324.

  • 1

    Benabid AL, , Pollak P, , Gervason C, , Hoffmann D, , Gao DM, & Hommel M, : Long-term suppression of tremor by chronic stimulation of the ventral intermediate thalamic nucleus. Lancet 337:403406, 1991

    • Search Google Scholar
    • Export Citation
  • 2

    Burchiel KJ, The future of microelectrode recording. Israel Z, & Burchiel K: Microelectrode Recording in Movement Disorder Surgery New York, Thieme, 2004. 208210

    • Search Google Scholar
    • Export Citation
  • 3

    Burchiel KJ, , Anderson VC, , Favre J, & Hammerstad JP: Comparison of pallidal and subthalamic nucleus deep brain stimulation for advanced Parkinson's disease: results of a randomized, blinded pilot study. Neurosurgery 45:13751384, 1999

    • Search Google Scholar
    • Export Citation
  • 4

    Deuschl G, , Schade-Brittinger C, , Krack P, , Volkmann J, , Schäfer H, & Bötzel K, : A randomized trial of deep-brain stimulation for Parkinson's disease. N Engl J Med 355:896908, 2006

    • Search Google Scholar
    • Export Citation
  • 5

    Hariz MI: Safety and risk of microelectrode recording in surgery for movement disorders. Stereotact Funct Neurosurg 78:146157, 2002

  • 6

    Henderson JM, , Holloway KL, , Gaede SE, & Rosenow JM: The application accuracy of a skull-mounted trajectory guide system for image-guided functional neurosurgery. Comput Aided Surg 9:155160, 2004

    • Search Google Scholar
    • Export Citation
  • 7

    Kupsch A, , Benecke R, , Müller J, , Trottenberg T, , Schneider GH, & Poewe W, : Pallidal deep-brain stimulation in primary generalized or segmental dystonia. N Engl J Med 355:19781990, 2006

    • Search Google Scholar
    • Export Citation
  • 8

    Schaltenbrand G, & Wahren W: Atlas for Stereotaxy of the Human Brain ed 2 Stuttgart, Thieme, 1977

  • 9

    Servello D, , Porta M, , Sassi M, , Brambilla A, & Robertson MM: Deep brain stimulation in 18 patients with severe Gilles de la Tourette syndrome refractory to treatment: the surgery and stimulation. J Neurol Neurosurg Psychiatry 79:136142, 2008

    • Search Google Scholar
    • Export Citation
  • 10

    Shahlaie K, , Larson PS, & Starr PA: Intraoperative computed tomography for deep brain stimulation surgery: technique and accuracy assessment. Neurosurgery 68:1 Suppl Operative 114124, 2011

    • Search Google Scholar
    • Export Citation
  • 11

    Starr PA, , Christine CW, , Theodosopoulos PV, , Lindsey N, , Byrd D, & Mosley A, : Implantation of deep brain stimulators into the subthalamic nucleus: technical approach and magnetic resonance imaging-verified lead locations. J Neurosurg 97:370387, 2002

    • Search Google Scholar
    • Export Citation
  • 12

    Starr PA, , Martin AJ, , Ostrem JL, , Talke P, , Levesque N, & Larson PS: Subthalamic nucleus deep brain stimulator placement using high-field interventional magnetic resonance imaging and a skull-mounted aiming device: technique and application accuracy. Clinical article. J Neurosurg 112:479490, 2010

    • Search Google Scholar
    • Export Citation
  • 13

    Sudhyadhom A, , Haq IU, , Foote KD, , Okun MS, & Bova FJ: A high resolution and high contrast MRI for differentiation of subcortical structures for DBS targeting: the Fast Gray Matter Acquisition T1 Inversion Recovery (FGATIR). Neuroimage 47:Suppl 2 T44T52, 2009

    • Search Google Scholar
    • Export Citation
  • 14

    Theodosopoulos PV, , Marks WJ Jr, , Christine C, & Starr PA: Locations of movement-related cells in the human subthalamic nucleus in Parkinson's disease. Mov Disord 18:791798, 2003

    • Search Google Scholar
    • Export Citation
  • 15

    Vidailhet M, , Vercueil L, , Houeto JL, , Krystkowiak P, , Benabid AL, & Cornu P, : Bilateral deep-brain stimulation of the globus pallidus in primary generalized dystonia. N Engl J Med 352:459467, 2005

    • Search Google Scholar
    • Export Citation
  • 16

    Weaver FM, , Follett K, , Stern M, , Hur K, , Harris C, & Marks WJ Jr, : Bilateral deep brain stimulation vs best medical therapy for patients with advanced Parkinson disease: a randomized controlled trial. JAMA 301:6373, 2009

    • Search Google Scholar
    • Export Citation
  • 17

    Zrinzo L, , Foltynie T, , Limousin P, & Hariz MI: Reducing hemorrhagic complications in functional neurosurgery: a large case series and systematic literature review. Clinical article. J Neurosurg 116:8494, 2012

    • Search Google Scholar
    • Export Citation

Metrics

All Time Past Year Past 30 Days
Abstract Views 1158 748 44
Full Text Views 574 105 9
PDF Downloads 305 75 5
EPUB Downloads 0 0 0