Editorial: Monitoring

Restricted access

If the inline PDF is not rendering correctly, you can download the PDF file here.

Article Information

Please include this information when citing this paper: published online April 29, 2011; DOI: 10.3171/2010.11.SPINE10612.

© AANS, except where prohibited by US copyright law.

Headings

References

  • 1

    Beatty RMMcGuire PMoroney JMHolladay FP: Continuous intraoperative electromyographic recording during spinal surgery. J Neurosurg 82:4014051995

  • 2

    Parker SLAmin AGFarber SHMcGirt MJSciubba DMWolinsky JP: Ability of electromyographic monitoring to determine the presence of malpositioned pedicle screws in the lumbosacral spine: analysis of 2450 consecutively placed screws. Clinical article. J Neurosurg Spine [epub ahead of print April 29 2011. DOI: 10.3171/2011.3.SPINE101]

  • 3

    Raynor BLLenke LGBridwell KHTaylor BAPadberg AM: Correlation between low triggered electromyographic thresholds and lumbar pedicle screw malposition: analysis of 4857 screws. Spine 32:267326782007

  • 4

    Sutter MAEggspuehler AGrob DPorchet FJeszenszky DDvorak J: Multimodal intraoperative monitoring (MIOM) during 409 lumbosacral surgical procedures in 409 patients. Eur Spine J 16:Suppl 2S221S2282007

  • 5

    Wang MYPineiro GMummaneni PV: Stimulus-evoked electromyography testing of percutaneous pedicle screws for the detection of pedicle breaches: a clinical study of 409 screws in 93 patients. Clinical article. J Neurosurg Spine 13:6006052010

  • 6

    Welch WCRose RDBalzer JRJacobs GB: Evaluation with evoked and spontaneous electromyography during lumbar instrumentation: a prospective study. J Neurosurg 87:3974021997

  • 1

    Glassman SDDimar JRPuno RMJohnson JRShields CBLinden RD: A prospective analysis of intraoperative electromyographic monitoring of pedicle screw placement with computed tomographic scan confirmation. Spine (Phila Pa 1976) 20:137513791995

  • 2

    Lenke LGPadberg AMRusso MHBridwell KHGelb DE: Triggered electromyographic threshold for accuracy of pedicle screw placement. An animal model and clinical correlation. Spine (Phila Pa 1976) 20:158515911995

  • 3

    Maguire JWallace SMadiga RLeppanen RDraper V: Evaluation of intrapedicular screw position using intraoperative evoked electromyography. Spine (Phila Pa 1976) 20:106810741995

  • 4

    Parker SLMcGirt MJFarber SHAmin AGRick AMSuk I: Accuracy of free-hand pedicle screws in the thoracic and lumbar spine: analysis of 6816 consecutive screws. Neurosurgery 68:1701782011

TrendMD

Metrics

Metrics

All Time Past Year Past 30 Days
Abstract Views 44 44 1
Full Text Views 47 47 0
PDF Downloads 163 163 0
EPUB Downloads 0 0 0

PubMed

Google Scholar