Search Results

You are looking at 1 - 3 of 3 items for

  • Author or Editor: Ioannis Vasilikos x
Clear All Modify Search
Free access

Ulrich Hubbe, Pamela Franco-Jimenez, Jan-Helge Klingler, Ioannis Vasilikos, Christoph Scholz and Evangelos Kogias

OBJECT

The aim of the study was to investigate the safety and efficacy of minimally invasive tubular microdiscectomy for the treatment of recurrent lumbar disc herniation (LDH). As opposed to endoscopic techniques, namely microendoscopic and endoscopic transforaminal discectomy, this microscopically assisted technique has never been used for the treatment of recurrent LDH.

METHODS

Thirty consecutive patients who underwent minimally invasive tubular microdiscectomy for recurrent LDH were included in the study. The preoperative and postoperative visual analog scale (VAS) scores for pain, the clinical outcome according to modified Macnab criteria, and complications were analyzed retrospectively. The minimum follow-up was 1.5 years. Student t-test with paired samples was used for the statistical comparison of pre- and postoperative VAS scores. A p value < 0.05 was considered to be statistically significant.

RESULTS

The mean operating time was 90 ± 35 minutes. The VAS score for leg pain was significantly reduced from 5.9 ± 2.1 preoperatively to 1.7 ± 1.3 postoperatively (p < 0.001). The overall success rate (excellent or good outcome according to Macnab criteria) was 90%. Incidental durotomy occurred in 5 patients (16.7%) without neurological consequences, CSF fistula, or negative influence to the clinical outcome. Instability occurred in 2 patients (6.7%).

CONCLUSIONS

The clinical outcome of minimally invasive tubular microdiscectomy is comparable to the reported success rates of other minimally invasive techniques. The dural tear rate is not associated to higher morbidity or worse outcome. The technique is an equally effective and safe treatment option for recurrent LDH.

Full access

Juergen Grauvogel, Christian Scheiwe, Waseem Masalha, Tanja Grauvogel, Jan Kaminsky and Ioannis Vasilikos

Current approaches for resection of petrous bone cholesteatomas (PBCs), such as canal wall up (closed) and canal wall down (open) mastoidectomies, in the pediatric population present recurrence rates ranging between 17% and 70% with a high rate of postoperative complications involving hearing loss and facial nerve weakness. This technical note illustrates an alternative intracranial approach that was used in combination with the techniques of piezoelectric surgery, neuroendoscopy, and neuronavigation for safe and effective removal in a difficult pediatric case of recurrent PBC.

The third recurrence of a PBC in a 14-year-old girl was diagnosed by CT and MRI. A retrosigmoid approach gave access to the petrous apex, allowing for the safe and complete removal of the lesion and decompression of the facial nerve and internal carotid artery. The intraoperative implementation of piezoelectric surgery, neuronavigation, neuroendoscopy, and neuromonitoring ensured better intraoperative visualization, safer bone removal, and preservation of nerve function, facilitating a macroscopically total resection of the pathology without additional neurological damage of the adjacent tissues.

Cholesteatoma extension could be clearly verified by intraoperative neuronavigation. Neuroendoscopy and piezoelectric surgery provided good support in the safe bone removal in close vicinity to neurovascular structures and in full vision inside the cholesteatoma cavity beyond the line of sight of the microscope. Hearing and facial nerve function could be preserved.

The presented intracranial retrosigmoid approach combined with multiple intraoperative assisting techniques proved to be effective for the safe and complete removal of recurrent PBC, providing excellent intraoperative visualization and the possibility of preserving cranial nerve function.

Restricted access

Jan-Helge Klingler, Ulrich Hubbe, Christoph Scholz, Florian Volz, Marc Hohenhaus, Ioannis Vasilikos, Waseem Masalha, Ralf Watzlawick and Yashar Naseri

OBJECTIVE

Intraoperative 3D imaging and navigation is increasingly used for minimally invasive spine surgery. A novel, noninvasive patient tracker that is adhered as a mask on the skin for 3D navigation necessitates a larger intraoperative 3D image set for appropriate referencing. This enlarged 3D image data set can be acquired by a state-of-the-art 3D C-arm device that is equipped with a large flat-panel detector. However, the presumably associated higher radiation exposure to the patient has essentially not yet been investigated and is therefore the objective of this study.

METHODS

Patients were retrospectively included if a thoracolumbar 3D scan was performed intraoperatively between 2016 and 2019 using a 3D C-arm with a large 30 × 30–cm flat-panel detector (3D scan volume 4096 cm3) or a 3D C-arm with a smaller 20 × 20–cm flat-panel detector (3D scan volume 2097 cm3), and the dose area product was available for the 3D scan. Additionally, the fluoroscopy time and the number of fluoroscopic images per 3D scan, as well as the BMI of the patients, were recorded.

RESULTS

The authors compared 62 intraoperative thoracolumbar 3D scans using the 3D C-arm with a large flat-panel detector and 12 3D scans using the 3D C-arm with a small flat-panel detector. Overall, the 3D C-arm with a large flat-panel detector required more fluoroscopic images per scan (mean 389.0 ± 8.4 vs 117.0 ± 4.6, p < 0.0001), leading to a significantly higher dose area product (mean 1028.6 ± 767.9 vs 457.1 ± 118.9 cGy × cm2, p = 0.0044).

CONCLUSIONS

The novel, noninvasive patient tracker mask facilitates intraoperative 3D navigation while eliminating the need for an additional skin incision with detachment of the autochthonous muscles. However, the use of this patient tracker mask requires a larger intraoperative 3D image data set for accurate registration, resulting in a 2.25 times higher radiation exposure to the patient. The use of the patient tracker mask should thus be based on an individual decision, especially taking into considering the radiation exposure and extent of instrumentation.