Serge Marbacher, Itai Mendelowitsch, Basil Erwin Grüter, Michael Diepers, Luca Remonda and Javier Fandino

OBJECTIVE

During the last decade, improvements in real-time, high-resolution imaging of surgically exposed cerebral vasculature have been realized with the successful introduction of intraoperative indocyanine green video angiography (ICGVA) and technical advances in intraoperative digital subtraction angiography (DSA). With the availability of 3D intraoperative DSA (3D-iDSA) in hybrid operating rooms, the present study offers a contemporary comparison for rates of accuracy and discordance.

METHODS

In this retrospective study of prospectively collected data, 140 consecutive patients underwent microsurgical treatment of intracranial aneurysms (IAs) in a hybrid operating room. Variables analyzed included patient demographics, aneurysm-specific characteristics, intraoperative ICGVA and 3D-iDSA findings, and the need for intraoperative clip readjustment. The authors defined the discordance rate of the two modalities as a false-negative finding that necessitated clip repositioning after 3D-iDSA.

RESULTS

In 120 patients, ICGVA and 3D-iDSA were used to evaluate 134 IA obliterations. Of 215 clips used, 29 (14%) were repositioned intraoperatively, improving the surgical result in all 29 patients (24%). Repositioning was prompted by visual inspection and microvascular Doppler ultrasonography in 8 (28%), ICGVA in 13 (45%), and 3D-iDSA in 7 (24%) patients. Clip repositioning was needed in 7 patients (6%) based on 3D-iDSA, yielding an ICGVA accuracy rate of 94%. Five (71%) of the ICGVA–3D-iDSA discordances that prompted clip repositioning occurred at the anterior communicating artery complex.

CONCLUSIONS

A combination of vascular monitoring techniques most often achieved correct intraoperative interpretation of complete IA occlusion and parent artery integrity. Compared with 3D-iDSA imaging, ICGVA demonstrated high accuracy. Despite the relatively low discordance rate, iDSA was confirmed to be the gold standard. Improved imaging quality, including 3D-iDSA, supports its routine use in IA surgery, obviating the need for postoperative DSA.

Restricted access

Alexander Spiessberger, Fabio Strange, Basil Erwin Gruter, Stefan Wanderer, Daniela Casoni, Philipp Gruber, Michael Diepers, Luca Remonda, Javier Fandino, Javier Añon and Serge Marbacher

OBJECTIVE

Temporary parent vessel occlusion performed to establish a high-flow interpositional bypass carries the risk of infarcts. The authors investigated the feasibility of a novel technique to establish a high-flow bypass without temporary parent vessel occlusion in order to lower the risk of ischemic complications.

METHODS

In 10 New Zealand white rabbits, a carotid artery side-to-end anastomosis was performed under parent artery patency with a novel endovascular balloon device. Intraoperative angiography, postoperative neurological assessments, and postoperative MRI/MRA were performed to evaluate the feasibility and safety of the novel technique.

RESULTS

A patent anastomosis was established in 10 of 10 animals; 3 procedure-related complications occurred. No postoperative focal neurological deficits were observed. The MRI/MRA findings include no infarcts and bypass patency in 50% of the animals.

CONCLUSIONS

The authors demonstrated the feasibility of an endovascular assisted, nonocclusive high-flow bypass. Future refinement of the device and technique in an animal model is necessary to lower the complication rate and increase patency rates.