Search Results

You are looking at 1 - 5 of 5 items for

  • Author or Editor: Jacques Chiras x
  • By Author: Sourour, Nader-Antoine x
Clear All Modify Search
Full access

Joseph Gabrieli, Nader-Antoine Sourour, Dorian Chauvet, Federico Di Maria, Jacques Chiras and Frédéric Clarençon

The posterior inferior cerebellar artery (PICA) is a vessel located between the intra- and extracranial circulation. The artery is characterized by a complex embryological development and numerous anatomical variants. The authors present a case of the PICA supplied by both a hypertrophic anterior spinal artery and a hypoplastic bulbar artery. This unusual arrangement somehow completes the list of previously published variants, and the spontaneous rupture of a related aneurysm confirmed the fragility of this network. The authors discuss anatomical and treatment considerations.

Full access

Robert Fahed, Frédéric Clarençon, Nader-Antoine Sourour, Dorian Chauvet, Lise Le Jean, Jacques Chiras and Federico Di Maria

One of the procedural risks in arteriovenous malformation (AVM) embolization is possible migration of the embolic agent into the venous drainage with an incomplete nidus occlusion, which may lead to severe hemorrhagic complications.

This report presents the case of a 29-year-old man who presented with a deep intraparenchymal hematoma on the left side secondary to the spontaneous rupture of a claustral AVM. Upon resorption of the hematoma, the patient underwent an initial therapeutic session of N-butyl-2 cyanoacrylate endovascular embolization, with the purpose of reducing the AVM volume and flow before performing Gamma Knife radiosurgery. After glue injection into one of the arterial feeders, the control angiography showed a partial migration of the glue cast into the straight sinus, with most of the nidus still visible. Because of the bleeding risk due to possible venous hypertension, it was decided to try to retrieve the glue from the vein by using a stent retriever via jugular access. This maneuver allowed a nearly complete removal of the glue cast, thereby restoring normal venous flow drainage. The patient showed no clinical worsening after the procedure.

To the authors’ knowledge, this is the first report of the use of the Solitaire FR device as a rescue glue retriever. This method should be considered by physicians in cases of unintended glue migration into the venous circulation during AVM embolization.

Full access

Joseph Gabrieli, Frédéric Clarençon, Federico Di Maria, Robert Fahed, Anne-Laure Boch, Vincent Degos, Jacques Chiras and Nader-Antoine Sourour

Intracranial aneurysms are relatively frequently encountered in patients with brain arteriovenous malformations (BAVMs). They may be located on the circle of Willis, on arterial feeders, or even inside the nidus. Because BAVM-associated aneurysms represent a risk factor of bleeding, the question of the timing and modality of their management remains a matter of debate in unruptured BAVMs. The authors present a case of fatal periprocedural rupture of a flow-related aneurysm (FRA) during the removal of the microcatheter after injection of a liquid embolic agent. A 40-year-old man was treated at the authors' institution for the management of a Spetzler-Martin Grade III left unruptured frontal BAVM, revealed by seizures and a focal neurological deficit attributed to flow steal phenomenon. After a multidisciplinary meeting, endovascular treatment was considered to reduce the flow of the BAVM. A proximal FRA located on the feeding internal carotid artery (ICA) was purposely left untreated because it did not meet the criteria of the authors' institution for preventative treatment (i.e., small size [2.5 mm]). During embolization, at the time of microcatheter retrieval, and after glue injection, the aneurysm unexpectedly ruptured. The aneurysm's rupture was attributed to the stress (torsion/flexion) on the ICA caused by the microcatheter removal. Despite the attempts to manage the bleeding, the patient eventually died of the acute increase of intracranial pressure related to the massive subarachnoid hemorrhage. This case highlights a previously unreported mechanism of FRA rupture during BAVM embolization: the stress transmitted to the parent artery during the removal of the microcatheter.

Restricted access

Frédéric Clarençon, Federico Di Maria, Evelyne Cormier, Nader-Antoine Sourour, Eric Enkaoua, Frédéric Sailhan, Christina Iosif, Lise Le Jean and Jacques Chiras

Presurgical devascularization of hypervascular spinal metastases has been shown to be effective in preventing major blood loss during open surgery. Most often, embolization can be performed using polyvinyl alcohol (PVA) microparticles. However, in some cases, the close relationship between the feeders of the metastases and the feeders of the anterior spinal artery (ASA) poses a risk of spinal cord ischemia when PVA microparticle embolization is performed.

The authors present their early experience in the treatment of spinal metastases close to the ASA; in 2 cases they injected Onyx-18, by direct puncture, into hypervascular posterior arch spinal metastases situated close to the ASA.

Two women, one 36 and the other 55 years of age, who presented with spinal lesions (at the posterior arch of C-4 and T-6, respectively) from thyroid and a kidney tumors, were sent to the authors' department to undergo presurgical embolization. After having performed a complete spinal digital subtraction angiography study, a regular angiography catheter was positioned at the ostium of the artery that mainly supplied the lesion. Then, with the patient in the left lateral decubitus position, direct puncture with 18-gauge needles of the lesion was performed using roadmap guidance. Onyx-18 was injected through the needles under biplanar fluoroscopy.

Satisfactory devascularization of the lesions was obtained; the ASA remained patent in both cases. The metastases were surgically removed in both cases within the 48 hours after the embolization and major blood loss did not occur.

Presurgical devascularization of hypervascular spinal metastases close the ASA by direct puncture with Onyx-18 seems to be an effective technique and appears to be safe in terms of the preserving the ASA's patency.

Restricted access

Eimad Shotar, Matthieu Debarre, Nader-Antoine Sourour, Federico Di Maria, Joseph Gabrieli, Aurélien Nouet, Jacques Chiras, Vincent Degos and Frédéric Clarençon

OBJECTIVE

The authors aimed to design a score for stratifying patients with brain arteriovenous malformation (BAVM) rupture, based on the likelihood of a poor long-term neurological outcome.

METHODS

The records of consecutive patients with BAVM hemorrhagic events who had been admitted over a period of 11 years were retrospectively reviewed. Independent predictors of a poor long-term outcome (modified Rankin Scale score ≥ 3) beyond 1 year after admission were identified. A risk stratification scale was developed and compared with the intracranial hemorrhage (ICH) score to predict poor outcome and inpatient mortality.

RESULTS

One hundred thirty-five patients with 139 independent hemorrhagic events related to BAVM rupture were included in this analysis. Multivariate logistic regression followed by stepwise analysis showed that consciousness level according to the Glasgow Coma Scale (OR 6.5, 95% CI 3.1–13.7, p < 10−3), hematoma volume (OR 1.8, 95% CI 1.2–2.8, p = 0.005), and intraventricular hemorrhage (OR 7.5, 95% CI 2.66–21, p < 10−3) were independently associated with a poor outcome. A 12-point scale for ruptured BAVM prognostication was constructed combining these 3 factors. The score obtained using this new scale, the ruptured AVM prognostic (RAP) score, was a stronger predictor of a poor long-term outcome (area under the receiver operating characteristic curve [AUC] 0.87, 95% CI 0.8–0.92, p = 0.009) and inpatient mortality (AUC 0.91, 95% CI 0.85–0.95, p = 0.006) than the ICH score. For a RAP score ≥ 6, sensitivity and specificity for predicting poor outcome were 76.8% (95% CI 63.6–87) and 90.8% (95% CI 81.9–96.2), respectively.

CONCLUSIONS

The authors propose a new admission score, the RAP score, dedicated to stratifying the risk of poor long-term outcome after BAVM rupture. This easy-to-use scoring system may help to improve communication between health care providers and consistency in clinical research. Only external prospective cohorts and population-based studies will ensure full validation of the RAP scores' capacity to predict outcome after BAVM rupture.