Search Results

You are looking at 1 - 2 of 2 items for

  • Author or Editor: Nobuhito Saito x
  • By Author: Shono, Naoyuki x
Clear All Modify Search
Free access

Sunho Ko, Atsushi Nakazawa, Yusuke Kurose, Kanako Harada, Mamoru Mitsuishi, Shigeo Sora, Naoyuki Shono, Hirofumi Nakatomi, Nobuhito Saito and Akio Morita

OBJECTIVE

Advanced and intelligent robotic control is necessary for neurosurgical robots, which require great accuracy and precision. In this article, the authors propose methods for dynamically and automatically controlling the motion-scaling ratio of a master-slave neurosurgical robotic system to reduce the task completion time.

METHODS

Three dynamic motion-scaling modes were proposed and compared with the conventional fixed motion-scaling mode. These 3 modes were defined as follows: 1) the distance between a target point and the tip of the slave manipulator, 2) the distance between the tips of the slave manipulators, and 3) the velocity of the master manipulator. Five test subjects, 2 of whom were neurosurgeons, sutured 0.3-mm artificial blood vessels using the MM-3 neurosurgical robot in each mode.

RESULTS

The task time, total path length, and helpfulness score were evaluated. Although no statistically significant differences were observed, the mode using the distance between the tips of the slave manipulators improves the suturing performance.

CONCLUSIONS

Dynamic motion scaling has great potential for the intelligent and accurate control of neurosurgical robots.

Full access

Masanori Yoshino, Hirofumi Nakatomi, Taichi Kin, Toki Saito, Naoyuki Shono, Seiji Nomura, Daichi Nakagawa, Shunsaku Takayanagi, Hideaki Imai, Hiroshi Oyama and Nobuhito Saito

Successful resection of hemangioblastoma depends on preoperative assessment of the precise locations of feeding arteries and draining veins. Simultaneous 3D visualization of feeding arteries, draining veins, and surrounding structures is needed. The present study evaluated the usefulness of high-resolution 3D multifusion medical imaging (hr-3DMMI) for preoperative planning of hemangioblastoma. The hr-3DMMI combined MRI, MR angiography, thin-slice CT, and 3D rotated angiography. Surface rendering was mainly used for the creation of hr-3DMMI using multiple thresholds to create 3D models, and processing took approximately 3–5 hours. This hr-3DMMI technique was used in 5 patients for preoperative planning and the imaging findings were compared with the operative findings. Hr-3DMMI could simulate the whole 3D tumor as a unique sphere and show the precise penetration points of both feeding arteries and draining veins with the same spatial relationships as the original tumor. All feeding arteries and draining veins were found intraoperatively at the same position as estimated preoperatively, and were occluded as planned preoperatively. This hr-3DMMI technique could demonstrate the precise locations of feeding arteries and draining veins preoperatively and estimate the appropriate route for resection of the tumor. Hr-3DMMI is expected to be a very useful support tool for surgery of hemangioblastoma.