Freehand placement of depth electrodes using electromagnetic frameless stereotactic guidance

Technical note

Restricted access

The presurgical evaluation of patients with epilepsy often requires an intracranial study in which both subdural grid electrodes and depth electrodes are needed. Performing a craniotomy for grid placement with a stereotactic frame in place can be problematic, especially in young children, leading some surgeons to consider frameless stereotaxy for such surgery. The authors report on the use of a system that uses electromagnetic impulses to track the tip of the depth electrode. Ten pediatric patients with medically refractory focal lobar epilepsy required placement of both subdural grid and intraparenchymal depth electrodes to map seizure onset. Presurgical frameless stereotaxic targeting was performed using a commercially available electromagnetic image-guided system. Freehand depth electrode placement was then performed with intraoperative guidance using an electromagnetic system that provided imaging of the tip of the electrode, something that has not been possible using visually or sonically based systems. Accuracy of placement of depth electrodes within the deep structures of interest was confirmed postoperatively using CT and CT/MR imaging fusion. Depth electrodes were appropriately placed in all patients. Electromagnetic-tracking–based stereotactic targeting improves the accuracy of freehand placement of depth electrodes in patients with medically refractory epilepsy. The ability to track the electrode tip, rather than the electrode tail, is a major feature that enhances accuracy. Additional advantages of electromagnetic frameless guidance are discussed.

Article Information

Address correspondence to: Carter D. Wray, M.D., Seattle Children's Hospital, Division of Pediatric Neurology, MS B 5552, PO Box 5371, Seattle, Washington 98145. email: carterwraymd@gmail.com.

© AANS, except where prohibited by US copyright law.

Headings

Figures

  • View in gallery

    Case 9 (18-year-old patient with an insular cavernoma). A preoperative T2-weighted MR image with a coregistered depth electrode from a CT scan obtained immediately after electrode implantation using electromagnetic frameless stereotactic guidance.

References

1

Azeem SSOrigitano TC: Ventricular catheter placement with a frameless neuronavigational system: a 1-year experience. Neurosurgery 60:4 Suppl 22432482007

2

Blatt DRRoper SNFriedman WA: Invasive monitoring of limbic epilepsy using stereotactic depth and subdural strip electrodes: surgical technique. Surg Neurol 48:74791997

3

Chamoun RBNayar VVYoshor D: Neuronavigation applied to epilepsy monitoring with subdural electrodes. Neurosurg Focus 25:3E212008

4

Davies KGPhillips BLHermann BP: MRI confirmation of accuracy of freehand placement of mesial temporal lobe depth electrodes in the investigation of intractable epilepsy. Br J Neurosurg 10:1751781996

5

Dorward NLAlberti ODijkstra ABuurman JKitchen NDThomas DG: Clinical introduction of an adjustable rigid instrument holder for frameless stereotactic interventions. Comput Aided Surg 2:1801851997

6

Kratimenos GPThomas DGShorvon SDFish DR: Stereotactic insertion of intracerebral electrodes in the investigation of epilepsy. Br J Neurosurg 7:45521993

7

Mascott CR: In vivo accuracy of image guidance performed using optical tracking and optimized registration. J Neurosurg 105:5615672006

8

McMillen JLVonau MWood MJ: Pinless frameless electromagnetic image-guided neuroendoscopy in children. Childs Nerv Syst 26:8718782010

9

Mehta ADLabar DDean AHarden CHosain SPak J: Frameless stereotactic placement of depth electrodes in epilepsy surgery. J Neurosurg 102:104010452005

10

Muacevic AUhl ESteiger HJReulen HJ: Accuracy and clinical applicability of a passive marker based frameless neuronavigation system. J Clin Neurosci 7:4144182000

11

Murphy MAO'Brien TJCook MJ: Insertion of depth electrodes with or without subdural grids using frameless stereotactic guidance systems—technique and outcome. Br J Neurosurg 16:1191252002

12

Ortler MSohm FEisner WBauer RDobesberger JTrinka E: Frame-based vs frameless placement of intrahippocampal depth electrodes in patients with refractory epilepsy: a comparative in vivo (application) study. Neurosurgery 68:8818872011

13

Reavey-Cantwell JFBova FJPincus DW: Frameless, pinless stereotactic neurosurgery in children. J Neurosurg 104:6 Suppl3923952006

14

Rosenow JMSootsman WK: Application accuracy of an electromagnetic field-based image-guided navigation system. Stereotact Funct Neurosurg 85:75812007

15

Ross DABrunberg JADrury IHenry TR: Intracerebral depth electrode monitoring in partial epilepsy: the morbidity and efficacy of placement using magnetic resonance imageguided stereotactic surgery. Neurosurgery 39:3273341996

16

Shenai MBRoss DASagher O: The use of multiplanar trajectory planning in the stereotactic placement of depth electrodes. Neurosurgery 60:4 Suppl 22722762007

17

Song JKAbou-Khalil BKonrad PE: Intraventricular monitoring for temporal lobe epilepsy: report on technique and initial results in eight patients. J Neurol Neurosurg Psychiatry 74:5615652003

18

Spencer SSSpencer DDWilliamson PDMattson R: Combined depth and subdural electrode investigation in uncontrolled epilepsy. Neurology 40:74791990

19

Spire WJJobst BCThadani VMWilliamson PDDarcey TMRoberts DW: Robotic image-guided depth electrode implantation in the evaluation of medically intractable epilepsy. Neurosurg Focus 25:3E192008

20

Stone SSRutka JT: Utility of neuronavigation and neuromonitoring in epilepsy surgery. Neurosurg Focus 25:3E172008

21

Stuart RMGoodman RR: Novel use of a custom stereotactic frame for placement of depth electrodes for epilepsy monitoring. Neurosurg Focus 25:3E202008

22

Talairach JSzikla G: Application of stereotactic concepts to the surgery of epilepsy. Acta Neurochir Suppl (Wien) 30:35541980

23

Van Roost DSolymosi LSchramm Jvan Oosterwyck BElger CE: Depth electrode implantation in the length axis of the hippocampus for the presurgical evaluation of medial temporal lobe epilepsy: a computed tomography-based stereotactic insertion technique and its accuracy. Neurosurgery 43:8198271998

24

Yeh HSTaha JMTobler WD: Implantation of intracerebral depth electrodes for monitoring seizures using the Pelorus stereotactic system guided by magnetic resonance imaging. Technical note. J Neurosurg 78:1381411993

TrendMD

Metrics

Metrics

All Time Past Year Past 30 Days
Abstract Views 3 3 3
Full Text Views 15 15 12
PDF Downloads 29 29 18
EPUB Downloads 0 0 0

PubMed

Google Scholar