Editorial

Translaminar screws

Restricted access

If the inline PDF is not rendering correctly, you can download the PDF file here.

Article Information

Please include this information when citing this paper: DOI: 10.3171/2011.8.PEDS11339.

© AANS, except where prohibited by US copyright law.

Headings

References

  • 1

    Boucher HH: A method of spinal fusion. J Bone Joint Surg [Br] 41-B:2482591959

  • 2

    Claybrooks RKayanja MMilks RBenzel E: Atlantoaxial fusion: a biomechanical analysis of two C1–C2 fusion techniques. Spine J 7:6826882007

  • 3

    Gorek JAcaroglu EBerven SYousef APuttlitz CM: Constructs incorporating intralaminar C2 screws provide rigid stability for atlantoaxial fixation. Spine (Phila Pa 1976) 30:151315182005

  • 4

    Jea ASheth RNVanni SGreen BALevi AD: Modification of Wright's technique for placement of bilateral crossing C2 translaminar screws: technical note. Spine J 8:6566602008

  • 5

    Kretzer RMSciubba DMBagley CAWolinsky JPGokaslan ZLGaronzik IM: Translaminar screw fixation in the upper thoracic spine. J Neurosurg Spine 5:5275332006

  • 6

    Lapsiwala SBAnderson PAOza AResnick DK: Biomechanical comparison of four C1 to C2 rigid fixative techniques: anterior transarticular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws. Neurosurgery 58:5165212006

  • 7

    Leonard JRWright NM: Pediatric atlantoaxial fixation with bilateral, crossing C-2 translaminar screws. J Neurosurg 104:1 Suppl59632006

  • 8

    Lewis SJCanavese FKeetbaas S: Intralaminar screw insertion of thoracic spine in children with severe spinal deformities: two case reports. Spine (Phila Pa 1976) 34:E251E2542009

  • 9

    Molina CSciubba DMChaput CTortolani PJJallo GIKretzer RM: A computed tomography–based feasibility study of translaminar screw placement in the pediatric thoracic spine. Laboratory investigation. J Neurosurg Pediatr 9:27342012

  • 10

    Patel AJCherian JFulkerson DHFox BDChern JJWhitehead WE: Computed tomography morphometric analysis for translaminar screw fixation in the upper thoracic spine of the pediatric population. Clinical article. J Neurosurg Pediatr 7:3833882011

  • 11

    Reddy CIngalhalikar AVChannon SLim THTorner JHitchon PW: In vitro biomechanical comparison of transpedicular versus translaminar C-2 screw fixation in C2–3 instrumentation. J Neurosurg Spine 7:4144182007

  • 12

    Viswanathan AJohnson KKWhitehead WECurry DJLuerssen TGJea A: Hybrid spinal constructs using sublaminar polyester bands in posterior instrumented fusions in children: a series of 5 cases. Neurosurgery 66:8628672010

  • 13

    Wang MY: C2 crossing laminar screws: cadaveric morphometric analysis. Neurosurgery 59:1 Suppl 1ONS84ONS882006

  • 14

    Wright NM: Posterior C2 fixation using bilateral, crossing C2 laminar screws: case series and technical note. J Spinal Disord Tech 17:1581622004

  • 1

    Kretzer RMHu NKikkawa JGaronzik IMJallo GITortolani PJ: Surgical management of two-versus three-column injuries of the cervicothoracic junction: biomechanical comparison of translaminar screw and pedicle screw fixation using a cadaveric model. Spine (Phila Pa 1976) 35:E948E9542010

TrendMD

Metrics

Metrics

All Time Past Year Past 30 Days
Abstract Views 31 31 2
Full Text Views 101 101 1
PDF Downloads 112 112 1
EPUB Downloads 0 0 0

PubMed

Google Scholar