Restricted access

Zach Pennington, Daniel Lubelski, Erick M. Westbroek, A. Karim Ahmed, Jeff Ehresman, Matthew L. Goodwin, Sheng-Fu Lo, Timothy F. Witham, Ali Bydon, Nicholas Theodore and Daniel M. Sciubba

OBJECTIVE

Postoperative C5 palsy affects 7%–12% of patients who undergo posterior cervical decompression for degenerative cervical spine pathologies. Minimal evidence exists regarding the natural history of expected recovery and variables that affect palsy recovery. The authors investigated pre- and postoperative variables that predict recovery and recovery time among patients with postoperative C5 palsy.

METHODS

The authors included patients who underwent posterior cervical decompression at a tertiary referral center between 2004 and 2018 and who experienced postoperative C5 palsy. All patients had preoperative MR images and full records, including operative note, postoperative course, and clinical presentation. Kaplan-Meier survival analysis was used to evaluate both times to complete recovery and to new neurological baseline—defined by deltoid strength on manual motor testing of the affected side—as a function of clinical symptoms, surgical maneuvers, and the severity of postoperative deficits.

RESULTS

Seventy-seven patients were included, with an average age of 64 years. The mean follow-up period was 17.7 months. The mean postoperative C5 strength was grade 2.7/5, and the mean time to first motor examination with documented C5 palsy was 3.5 days. Sixteen patients (21%) had bilateral deficits, and 9 (12%) had new-onset biceps weakness; 36% of patients had undergone C4–5 foraminotomy of the affected root, and 17% had presented with radicular pain in the dermatome of the affected root. On univariable analysis, patients’ reporting of numbness or tingling (p = 0.02) and a baseline deficit (p < 0.001) were the only predictors of time to recovery. Patients with grade 4+/5 weakness had significantly shorter times to recovery than patients with grade 4/5 weakness (p = 0.001) or ≤ grade 3/5 weakness (p < 0.001). There was no difference between those with grade 4/5 weakness and those with ≤ grade 3/5 weakness. Patients with postoperative strength < grade 3/5 had a < 50% chance of achieving complete recovery.

CONCLUSIONS

The timing and odds of recovery following C5 palsy were best predicted by the magnitude of the postoperative deficit. The use of C4–5 foraminotomy did not predict the time to or likelihood of recovery.

Restricted access

Wataru Ishida, Joshua Casaos, Arun Chandra, Adam D’Sa, Seba Ramhmdani, Alexander Perdomo-Pantoja, Nicholas Theodore, George Jallo, Ziya L. Gokaslan, Jean-Paul Wolinsky, Daniel M. Sciubba, Ali Bydon, Timothy F. Witham and Sheng-Fu L. Lo

OBJECTIVE

With the advent of intraoperative electrophysiological neuromonitoring (IONM), surgical outcomes of various neurosurgical pathologies, such as brain tumors and spinal deformities, have improved. However, its diagnostic and therapeutic value in resecting intradural extramedullary (ID-EM) spinal tumors has not been well documented in the literature. The objective of this study was to summarize the clinical results of IONM in patients with ID-EM spinal tumors.

METHODS

A retrospective patient database review identified 103 patients with ID-EM spinal tumors who underwent tumor resection with IONM (motor evoked potentials, somatosensory evoked potentials, and free-running electromyography) from January 2010 to December 2015. Patients were classified as those without any new neurological deficits at the 6-month follow-up (group A; n = 86) and those with new deficits (group B; n = 17). Baseline characteristics, clinical outcomes, and IONM findings were collected and statistically analyzed. In addition, a meta-analysis in compliance with the PRISMA guidelines was performed to estimate the overall pooled diagnostic accuracy of IONM in ID-EM spinal tumor resection.

RESULTS

No intergroup differences were discovered between the groups regarding baseline characteristics and operative data. In multivariate analysis, significant IONM changes (p < 0.001) and tumor location (thoracic vs others, p = 0.018) were associated with new neurological deficits at the 6-month follow-up. In predicting these changes, IONM yielded a sensitivity of 82.4% (14/17), specificity of 90.7% (78/86), positive predictive value (PPV) of 63.6% (14/22), negative predictive value (NPV) of 96.3% (78/81), and area under the curve (AUC) of 0.893. The diagnostic value slightly decreased in patients with schwannomas (AUC = 0.875) and thoracic tumors (AUC = 0.842). Among 81 patients who did not demonstrate significant IONM changes at the end of surgery, 19 patients (23.5%) exhibited temporary intraoperative exacerbation of IONM signals, which were recovered by interruption of surgical maneuvers; none of these patients developed new neurological deficits postoperatively. Including the present study, 5 articles encompassing 323 patients were eligible for this meta-analysis, and the overall pooled diagnostic value of IONM was a sensitivity of 77.9%, a specificity of 91.1%, PPV of 56.7%, and NPV of 95.7%.

CONCLUSIONS

IONM for the resection of ID-EM spinal tumors is a reasonable modality to predict new postoperative neurological deficits at the 6-month follow-up. Future prospective studies are warranted to further elucidate its diagnostic and therapeutic utility.

Free access

Corinna C. Zygourakis, A. Karim Ahmed, Samuel Kalb, Alex M. Zhu, Ali Bydon, Neil R. Crawford and Nicholas Theodore

The Excelsius GPS (Globus Medical, Inc.) was approved by the FDA in 2017. This novel robot allows for real-time intraoperative imaging, registration, and direct screw insertion through a rigid external arm—without the need for interspinous clamps or K-wires. The authors present one of the first operative cases utilizing the Excelsius GPS robotic system in spinal surgery. A 75-year-old man presented with severe lower back pain and left leg radiculopathy. He had previously undergone 3 decompressive surgeries from L3 to L5, with evidence of instability and loss of sagittal balance. Robotic assistance was utilized to perform a revision decompression with instrumented fusion from L3 to S1. The usage of robotic assistance in spinal surgery may be an invaluable resource in minimally invasive cases, minimizing the need for fluoroscopy, or in those with abnormal anatomical landmarks.

The video can be found here: https://youtu.be/yVI-sJWf9Iw.