Browse

You are looking at 1 - 3 of 3 items for

  • By Author: Reyes, Phillip M. x
  • By Author: Theodore, Nicholas x
  • By Author: Sonntag, Volker K. H. x
Clear All Modify Search
Restricted access

Ali A. Baaj, Phillip M. Reyes, Ali S. Yaqoobi, Juan S. Uribe, Fernando L. Vale, Nicholas Theodore, Volker K. H. Sonntag and Neil R. Crawford

Object

Unstable fractures at the thoracolumbar junction often require extended, posterior, segmental pedicular fixation. Some surgeons have reported good clinical outcomes with short-segment constructs if additional pedicle screws are inserted at the fractured level. The goal of this study was to quantify the biomechanical advantage of the index-level screw in a fracture model.

Methods

Six human cadaveric T10–L4 specimens were tested. A 3-column injury at L-1 was simulated, and 4 posterior constructs were tested as follows: one-above-one-below (short construct) with/without index-level screws, and two-above-two-below (long construct) with/without index-level screws. Pure moments were applied quasistatically while 3D motion was measured optoelectronically. The range of motion (ROM) and lax zone across T12–L2 were measured during flexion, extension, left and right lateral bending, and left and right axial rotation.

Results

All constructs significantly reduced the ROM and lax zone in the fractured specimens. With or without index-level screws, the long-segment constructs provided better immobilization than the short-segment constructs during all loading modes. Adding an index-level screw to the short-segment construct significantly improved stability during flexion and lateral bending; there was no significant improvement in stability when an index-level screw was added to the long-segment construct. Overall, bilateral index-level screws decreased the ROM of the 1-level construct by 25% but decreased the ROM of the 2-level construct by only 3%.

Conclusions

In a fracture model, adding index-level pedicle screws to short-segment constructs improves stability, although stability remains less than that provided by long-segment constructs with or without index-level pedicle screws. Therefore, highly unstable fractures likely require extended, long-segment constructs for optimum stability.

Restricted access

Bruno C. R. Lazaro, Fatih Ersay Deniz, Leonardo B. C. Brasiliense, Phillip M. Reyes, Anna G. U. Sawa, Nicholas Theodore, Volker K. H. Sonntag and Neil R. Crawford

Object

Posterior screw-rod fixation for thoracic spine trauma usually involves fusion across long segments. Biomechanical data on screw-based short-segment fixation for thoracic fusion are lacking. The authors compared the effects of spanning short and long segments in the thoracic spine.

Methods

Seven human spine segments (5 segments from T-2 to T-8; 2 segments from T-3 to T-9) were prepared. Pure-moment loading of 6 Nm was applied to induce flexion, extension, lateral bending, and axial rotation while 3D motion was measured optoelectronically. Normal specimens were tested, and then a wedge fracture was created on the middle vertebra after cutting the posterior ligaments. Five conditions of instrumentation were tested, as follows: Step A, 4-level fixation plus cross-link; Step B, 2-level fixation; Step C, 2-level fixation plus cross-link; Step D, 2-level fixation plus screws at fracture site (index); and Step E, 2-level fixation plus index screws plus cross-link.

Results

Long-segment fixation restricted 2-level range of motion (ROM) during extension and lateral bending significantly better than the most rigid short-segment construct. Adding index screws in short-segment constructs significantly reduced ROM during flexion, lateral bending, and axial rotation (p < 0.03). A cross-link reduced axial rotation ROM (p = 0.001), not affecting other loading directions (p > 0.4).

Conclusions

Thoracic short-segment fixation provides significantly less stability than long-segment fixation for the injury studied. Adding a cross-link to short fixation improved stability only during axial rotation. Adding a screw at the fracture site improved short-segment stability by an average of 25%.

Restricted access

Eric M. Horn, Phillip M. Reyes, Seungwon Baek, Mehmet Senoglu, Nicholas Theodore, Volker K. H. Sonntag and Neil R. Crawford

Object

The small diameter of the pedicle can make C-7 pedicle screw insertion dangerous. Although transfacet screws have been studied biomechanically when used in pinning joints, they have not been well studied when used as part of a C7–T1 screw/rod construct. The authors therefore compared C7–T1 fixation using a C-7 transfacet screw/T-1 pedicle screw construct with a construct composed of pedicle screws at both levels.

Methods

Each rigid posterior screw/rod construct was placed in 7 human cadaveric C6–T2 specimens (14 total). Specimens were tested in normal condition, after 2-column instability, and once fixated. Nondestructive, nonconstraining pure moments (maximum 1.5 Nm) were applied to induce flexion, extension, lateral bending, and axial rotation while recording 3D motion optoelectronically. The entire construct was then loaded to failure by dorsal linear force.

Results

There was no significant difference in angular range of motion between the 2 instrumented groups during any loading mode (p > 0.11, nonpaired t-tests). Both constructs reduced motion to < 2° in any direction and allowed significantly less motion than in the normal condition. The C-7 facet screw/T-1 pedicle screw construct allowed a small but significantly greater lax zone than the pedicle screw/rod construct during lateral bending, and it failed under significantly less load than the pedicle screw/rod construct (p < 0.001).

Conclusions

When C-7 transfacet screws are connected to T-1 pedicle screws, they provide equivalent stability of constructs formed by pedicle screws at both levels. Although less resistant to failure, the transfacet screw construct should be a viable alternative in patients with healthy bone.