Effective accuracy of stereoelectroencephalography: robotic 3D versus Talairach orthogonal approaches

Restricted access

OBJECTIVE

Stereoelectroencephalography (SEEG) was first developed in the 1950s by Jean Talairach using 2D angiography and a frame-based, orthogonal approach through a metallic grid. Since then, various other frame-based and frameless techniques have been described. In this study the authors sought to compare the traditional orthogonal Talairach 2D angiographic approach with a frame-based 3D robotic procedure that included 3D angiographic interoperative imaging guidance. MRI was used for both procedures during surgery, but MRI preplanning was done only in the robotic 3D technique.

METHODS

All study patients suffered from drug-resistant focal epilepsy and were treated at the same center by the same neurosurgical team. Fifty patients who underwent the 3D robotic procedure were compared to the same number of historical controls who had previously been successfully treated with the Talairach orthogonal procedure. The effectiveness and absolute accuracy, as well as safety, of the two procedures were compared. Moreover, in the 3D robotic group, the reliability of the preoperative MRI to avoid vascular structures was evaluated by studying the rate of trajectory modification following the coregistration of the intraoperative 3D angiographic data onto the preoperative MRI-based trajectory plans.

RESULTS

Effective accuracy (96.5% vs 13.7%) and absolute accuracy (1.15 mm vs 4.00 mm) were significantly higher in the 3D robotic group than in the Talairach orthogonal group. Both procedures showed excellent safety results (no major complications). The rate of electrode modification after 3D angiography was 43.8%, and it was highest for frontal and insular locations.

CONCLUSIONS

The frame-based, 3D angiographic, robotic procedure described here provided better accuracy for SEEG implantations than the traditional Talairach approach. This study also highlights the potential safety advantage of trajectory planning using intraoperative frame-based 3D angiography over preoperative MRI alone.

ABBREVIATIONS AP = anteroposterior; EEG = electroencephalography; MEG = magnetoencephalography; SEEG = stereoelectroencephalography.
Article Information

Contributor Notes

Correspondence Pierre Bourdillon: P. Wertheimer Hospital, Hospices Civils de Lyon, Bron, France. pierre.bourdillon@neurochirurgie.fr.INCLUDE WHEN CITING Published online December 7, 2018; DOI: 10.3171/2018.7.JNS181164.

P.B. and C.E.C. contributed equally to this work.

Disclosures The authors report no conflict of interest concerning the materials or methods used in this study or the findings specified in this paper.
Headings
References
  • 1

    Apra CBourdillon PLévêque M: Surgical techniques: when brain bullets met crowdfunding. Nature 530:1602016

  • 2

    Bourdillon PApra CLévêque M: First clinical use of stereotaxy in humans: the key role of x-ray localization discovered by Gaston Contremoulins. J Neurosurg 128:9329372018

    • Search Google Scholar
    • Export Citation
  • 3

    Bourdillon PApra CLévêque MVinckier F: Neuroplasticity and the brain connectome: what can Jean Talairach’s reflections bring to modern psychosurgery? Neurosurg Focus 43(3):E112017

    • Search Google Scholar
    • Export Citation
  • 4

    Bourdillon PIsnard JCatenoix HMontavont ARheims SRyvlin P: Stereo-electro-encephalography-guided radiofrequency thermocoagulation: from in vitro and in vivo data to technical guidelines. World Neurosurg 94:73792016

    • Search Google Scholar
    • Export Citation
  • 5

    Bourdillon PIsnard JCatenoix HMontavont ARheims SRyvlin P: Stereo electroencephalography-guided radiofrequency thermocoagulation (SEEG-guided RF-TC) in drug-resistant focal epilepsy: results from a 10-year experience. Epilepsia 58:85932017

    • Search Google Scholar
    • Export Citation
  • 6

    Bourdillon PLévêque MApra C: Second World War: Paris neurosurgeon’s map outwitted Nazis. Nature 547:2812017

  • 7

    Bourdillon PRyvlin PIsnard JMontavont ACatenoix HMauguière F: Stereotactic electroencephalography is a safe procedure, including for insular implantations. World Neurosurg 99:3533612017

    • Search Google Scholar
    • Export Citation
  • 8

    Budke MAvecillas-Chasin JMVillarejo F: Implantation of depth electrodes in children using VarioGuide frameless navigation system: technical note. Oper Neurosurg (Hagerstown Md) 15:3023092018

    • Search Google Scholar
    • Export Citation
  • 9

    Cardinale F: Talairach methodology in the era of 3D multimodal imaging: “the song remains the same,” but catchier, and therefore more helpful for clinical decision making and surgical planning in epilepsy surgery. Epilepsia 56:9769772015

    • Search Google Scholar
    • Export Citation
  • 10

    Cardinale FCossu MCastana LCasaceli GSchiariti MPMiserocchi A: Stereoelectroencephalography: surgical methodology, safety, and stereotactic application accuracy in 500 procedures. Neurosurgery 72:3533662013

    • Search Google Scholar
    • Export Citation
  • 11

    Châtillon CEMok KHall JOlivier A: Comparative study of manual versus robot-assisted frameless stereotaxy for intracranial electrode implantation. Presented at the 65th AES Annual Meeting, Baltimore, 2011 (Poster) (http://www.medtechsurgical.com/Pressroom/Peer-review) [Accessed August 23 2018]

    • Search Google Scholar
    • Export Citation
  • 12

    Cossu MFuschillo DCardinale FCastana LFrancione SNobili L: Stereo-EEG-guided radio-frequency thermocoagulations of epileptogenic grey-matter nodular heterotopy. J Neurol Neurosurg Psychiatry 85:6116172014

    • Search Google Scholar
    • Export Citation
  • 13

    Fomenko ASerletis D: Robotic stereotaxy in cranial neurosurgery: a qualitative systematic review. Neurosurgery 83:6426502018

  • 14

    Geevarghese RO’Gorman Tuura RLumsden DESamuel MAshkan K: Registration accuracy of CT/MRI fusion for localisation of deep brain stimulation electrode position: an imaging study and systematic review. Stereotact Funct Neurosurg 94:1591632016

    • Search Google Scholar
    • Export Citation
  • 15

    Giller CAMornet PMoreau JF: The first formulation of image-based stereotactic principles: the forgotten work of Gaston Contremoulins. J Neurosurg 127:142614352017

    • Search Google Scholar
    • Export Citation
  • 16

    Guénot M: SEEG electrodes implantation using flat-panel x-ray detectors and robot in Scarabin JM (ed): Stereotaxy and Epilepsy Surgery. Montrouge, France: John Libbey Eurotext2012 pp 219244

    • Search Google Scholar
    • Export Citation
  • 17

    Guénot MIsnard JRyvlin PFischer CMauguière FSindou M: SEEG-guided RF thermocoagulation of epileptic foci: feasibility, safety, and preliminary results. Epilepsia 45:136813742004

    • Search Google Scholar
    • Export Citation
  • 18

    Guenot MIsnard JRyvlin PFischer COstrowsky KMauguiere F: Neurophysiological monitoring for epilepsy surgery: the Talairach SEEG method. StereoElectroEncephaloGraphy. Indications, results, complications and therapeutic applications in a series of 100 consecutive cases. Stereotact Funct Neurosurg 77:29322001

    • Search Google Scholar
    • Export Citation
  • 19

    Leksell L: The stereotaxic method and radiosurgery of the brain. Acta Chir Scand 102:3163191951

  • 20

    Mathon BClemenceau SHasboun DHabert MOBelaid HNguyen-Michel VH: Safety profile of intracranial electrode implantation for video-EEG recordings in drug-resistant focal epilepsy. J Neurol 262:269927122015

    • Search Google Scholar
    • Export Citation
  • 21

    Mullin JPShriver MAlomar SNajm IBulacio JChauvel P: Is SEEG safe? A systematic review and meta-analysis of stereo-electroencephalography-related complications. Epilepsia 57:3864012016

    • Search Google Scholar
    • Export Citation
  • 22

    Munari C: Depth electrode implantation at Hôpital Sainte Anne, Paris in Engel J Jr (ed): Surgical Treatment of the Epilepsies. New York: Raven Press1987 pp 583588

    • Search Google Scholar
    • Export Citation
  • 23

    Narizzano MArnulfo GRicci SToselli BTisdall MCanessa A: SEEG assistant: a 3DSlicer extension to support epilepsy surgery. BMC Bioinformatics 18:1242017

    • Search Google Scholar
    • Export Citation
  • 24

    Nowell MRodionov RDiehl BWehner TZombori GKinghorn J: A novel method for implementation of frameless StereoEEG in epilepsy surgery. Neurosurgery 10 (Suppl 4):5255342014

    • Search Google Scholar
    • Export Citation
  • 25

    Ollivier IBehr CCebula HTimofeev ABenmekhbi MValenti MP: Efficacy and safety in frameless robot-assisted stereo-electroencephalography (SEEG) for drug-resistant epilepsy. Neurochirurgie 63:2862902017

    • Search Google Scholar
    • Export Citation
  • 26

    Spiegel EAWycis HTMarks MLee AJ: Stereotaxic apparatus for operations on the human brain. Science 106:3493501947

  • 27

    Talairach JBancaud JBonis ASzikla GTournoux P: Functional stereotaxic exploration of epilepsy. Confin Neurol 22:3283311962

  • 28

    Varma TRKEldridge P: Use of the NeuroMate stereotactic robot in a frameless mode for functional neurosurgery. Int J Med Robot 2:1071132006

    • Search Google Scholar
    • Export Citation
TrendMD
Metrics

Metrics

All Time Past Year Past 30 Days
Abstract Views 10 10 10
Full Text Views 4 4 4
PDF Downloads 7 7 7
EPUB Downloads 0 0 0
PubMed
Google Scholar