Intraoperative computed tomography for intracranial electrode implantation surgery in medically refractory epilepsy

Restricted access

OBJECT

Accurate placement of intracranial depth and subdural electrodes is important in evaluating patients with medically refractory epilepsy for possible resection. Confirming electrode locations on postoperative CT scans does not allow for immediate replacement of malpositioned electrodes, and thus revision surgery is required in select cases. Intraoperative CT (iCT) using the Medtronic O-arm device has been performed to detect electrode locations in deep brain stimulation surgery, but its application in epilepsy surgery has not been explored. In the present study, the authors describe their institutional experience in using the O-arm to facilitate accurate placement of intracranial electrodes for epilepsy monitoring.

METHODS

In this retrospective study, the authors evaluated consecutive patients who had undergone subdural and/or depth electrode implantation for epilepsy monitoring between November 2010 and September 2012. The O-arm device is used to obtain iCT images, which are then merged with the preoperative planning MRI studies and reviewed by the surgical team to confirm final positioning. Minor modifications in patient positioning and operative field preparation are necessary to safely incorporate the O-arm device into routine intracranial electrode implantation surgery. The device does not obstruct surgeon access for bur hole or craniotomy surgery. Depth and subdural electrode locations are easily identified on iCT, which merge with MRI studies without difficulty, allowing the epilepsy surgical team to intraoperatively confirm lead locations.

RESULTS

Depth and subdural electrodes were implanted in 10 consecutive patients by using routine surgical techniques together with preoperative stereotactic planning and intraoperative neuronavigation. No wound infections or other surgical complications occurred. In one patient, the hippocampal depth electrode was believed to be in a suboptimal position and was repositioned before final wound closure. Additionally, 4 strip electrodes were replaced due to suboptimal positioning. Postoperative CT scans did not differ from iCT studies in the first 3 patients in the series and thus were not obtained in the final 7 patients. Overall, operative time was extended by approximately 10–15 minutes for O-arm positioning, less than 1 minute for image acquisition, and approximately 10 minutes for image transfer, fusion, and intraoperative analysis (total time 21–26 minutes).

CONCLUSIONS

The O-arm device can be easily incorporated into routine intracranial electrode implantation surgery in standard-sized operating rooms. The technique provides accurate 3D visualization of depth and subdural electrode contacts, and the intraoperative images can be easily merged with preoperative MRI studies to confirm lead positions before final wound closure. Intraoperative CT obviates the need for routine postoperative CT and has the potential to improve the accuracy of intracranial electroencephalography recordings and may reduce the necessity for revision surgery.

ABBREVIATIONSDBS = deep brain stimulation; EEG = electroencephalography; iCT = intraoperative CT; iMRI = intraoperative MRI.
Article Information

Contributor Notes

Correspondence Kiarash Shahlaie, Department of Neurological Surgery, University of California, Davis School of Medicine, 4860 Y St., Ste. 3740, Sacramento, CA 95817. email: krshahlaie@ucdavis.edu.INCLUDE WHEN CITING Published online October 31, 2014; DOI: 10.3171/2014.9.JNS13919.DISCLOSURE The authors report no conflict of interest concerning the materials or methods used in this study or the findings specified in this paper. This study was supported by the UC Davis Bronte Epilepsy Research Program.

© AANS, except where prohibited by US copyright law.

Headings
References
  • 1

    Caire FGantois CTorny FRanoux DMaubon AMoreau JJ: Intraoperative use of the Medtronic O-arm for deep brain stimulation procedures. Stereotact Funct Neurosurg 88:1091142010

    • Search Google Scholar
    • Export Citation
  • 2

    Chamoun RBNayar VVYoshor D: Neuronavigation applied to epilepsy monitoring with subdural electrodes. Neurosurg Focus 25:3E212008

  • 3

    Engle DJLunsford LD: Brain tumor resection guided by intraoperative computed tomography. J Neurooncol 4:3613701987

  • 4

    Erõss LBagó AGEntz LFabó DHalász PBalogh A: Neuronavigation and fluoroscopy-assisted subdural strip electrode positioning: a simple method to increase intraoperative accuracy of strip localization in epilepsy surgery. Technical note. J Neurosurg 110:3273312009

    • Search Google Scholar
    • Export Citation
  • 5

    Fiegele TFeuchtner GSohm FBauer RAnton JVGotwald T: Accuracy of stereotactic electrode placement in deep brain stimulation by intraoperative computed tomography. Parkinsonism Relat Disord 14:5955992008

    • Search Google Scholar
    • Export Citation
  • 6

    Hogan RELowe VJBucholz RD: Triple-technique (MR imaging, single-photon emission CT, and CT) coregistration for image-guided surgical evaluation of patients with intractable epilepsy. AJNR Am J Neuroradiol 20:105410581999

    • Search Google Scholar
    • Export Citation
  • 7

    Ito YSugimoto YTomioka MHasegawa YNakago KYagata Y: Clinical accuracy of 3D fluoroscopy-assisted cervical pedicle screw insertion. Clinical article. J Neurosurg Spine 9:4504532008

    • Search Google Scholar
    • Export Citation
  • 8

    Kitai RSato KIdo KSakuma THanda YKubota T: Single burr hole surgery for the spheno-orbital fibrous dysplasia using intraoperative computed tomography. Minim Invasive Neurosurg 48:44462005

    • Search Google Scholar
    • Export Citation
  • 9

    Kwan PSander JW: The natural history of epilepsy: an epidemiological view. J Neurol Neurosurg Psychiatry 75:137613812004

  • 10

    LaViolette PSRand SDEllingson BMRaghavan MLew SMSchmainda KM: 3D visualization of subdural electrode shift as measured at craniotomy reopening. Epilepsy Res 94:1021092011

    • Search Google Scholar
    • Export Citation
  • 11

    Miller KJMakeig SHebb AORao RPNdenNijs MOjemann JG: Cortical electrode localization from X-rays and simple mapping for electrocorticographic research: the “Location on Cortex” (LOC) package for MATLAB. J Neurosci Methods 162:3033082007

    • Search Google Scholar
    • Export Citation
  • 12

    Nottmeier EWSeemer WYoung PM: Placement of thoracolumbar pedicle screws using three-dimensional image guidance: experience in a large patient cohort. Clinical article. J Neurosurg Spine 10:33392009

    • Search Google Scholar
    • Export Citation
  • 13

    Rajasekaran SVidyadhara SShetty AP: Intra-operative Iso-C3D navigation for pedicle screw instrumentation of hangman's fracture: a case report. J Orthop Surg (Hong Kong) 15:73772007

    • Search Google Scholar
    • Export Citation
  • 14

    Shahlaie KLarson PSStarr PA: Intraoperative computed tomography for deep brain stimulation surgery: technique and accuracy assessment. Neurosurgery 68:1 Suppl Operative1141242011

    • Search Google Scholar
    • Export Citation
  • 15

    Sillanpää MSchmidt D: Natural history of treated childhood-onset epilepsy: prospective, long-term population-based study. Brain 129:6176242006

    • Search Google Scholar
    • Export Citation
  • 16

    Smith APBakay RA: Frameless deep brain stimulation using intraoperative O-arm technology. Clinical article. J Neurosurg 115:3013092011

    • Search Google Scholar
    • Export Citation
  • 17

    Villavicencio ATBurneikiene SBulsara KRThramann JJ: Intraoperative three-dimensional fluoroscopy-based computerized tomography guidance for percutaneous kyphoplasty. Neurosurg Focus 18:3E32005

    • Search Google Scholar
    • Export Citation
  • 18

    Zhang JWeir VFajardo LLin JHsiung HRitenour ER: Dosimetric characterization of a cone-beam O-arm imaging system. J XRay Sci Technol 17:3053172009

    • Search Google Scholar
    • Export Citation
TrendMD
Cited By
Metrics

Metrics

All Time Past Year Past 30 Days
Abstract Views 283 283 92
Full Text Views 319 225 4
PDF Downloads 187 131 5
EPUB Downloads 0 0 0
PubMed
Google Scholar